The store will not work correctly when cookies are disabled.
We use cookies to make your experience better.To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
The Aten’s PE0210S, a 10-outlet, 1U rack mount power distribution unit (PDU), provides IEC and NEMA output. It distributes power to 10 receptacles from a single plug with unfiltered electrical pass-through. The PE0210S also provides surge protection, prevents damage to your equipment from power surges and spikes. The integrated surge protector includes a LED indicator, letting you know the status of your equipment.
Features
Space saving -1U rack mount design
IEC or NEMA outlet models
Surge Protection
Over-current Protection
Aluminum material
Works with data centers, server rooms and telecom equipment
Diagram
Content
1x PE0210S Basic PDU 1x LIN2-314K-P42G Power cord1x User Instructions
Specifications
Function
PE0210SA
PE0210SB
PE0210SG
Electrical
Nominal Input Voltage
100-120 VAC
100-240 VAC
100-240 VAC
Maximum Input Current
20A Max (UL de-dated 16A Max)
20A Max (UL derating 16A Max)
16A (Max)
Input Frequency
50-60 Hz
50-60 Hz
50-60 Hz
Input Connection
For A Plug: NEMA L5-20P For A2 Plug:NEMA 5-20P
NEMA L6-20P
For G Plug: IEC-320 C20 For Z Plug: Chinese 16A
Input Power
2400VA(Max); 1920VA(UL de-rated)
4800VA(Max); 3840VA(UL de-rated)
3840VA(Max)
Outlet Type
(10) NEMA 5-20R
(10) IEC 320 C13
(10) IEC 320 C13
Maximum Output Current (Outlet)
20A Max (UL de-dated 16A Max)
15A Max (UL derating 12A Max)
10A (Max)
Maximum Output Current (Bank)
20A Max (UL de-dated 16A Max)
20A Max (UL derating 16A Max)
16A (Max)
Maximum Output Current (Total)
20A Max (UL de-dated 16A Max)
20A Max (UL derating 16A Max)
16A (Max)
OPD(Overcurrent Protection Device)
Yes
Yes
Yes
Physical Properties
Dimensions (L x W x H)
48.20 x 4.44 x 4.50 cm (18.98 x 1.75 x 1.77 in.)
48.20 x 4.44 x 4.50 cm (18.98 x 1.75 x 1.77 in.)
48.20 x 4.44 x 4.50 cm (18.98 x 1.75 x 1.77 in.)
Weight
0.67 kg ( 1.48 lb )
0.67 kg ( 1.48 lb )
0.67 kg ( 1.48 lb )
Power Cord Length
10ft(12#)
10ft(12#)
10ft(3*2.5mm2)
Environmental
Temperature (Operating / Storage)
0 – 40℃ / -20 – 60℃ *When the environmental temperature comes close 40 degrees, it is recommended to lower the load to 60% to comply to the safety regulations.
0 – 40℃ / -20 – 60℃ *When the environmental temperature comes close 40 degrees, it is recommended to lower the load to 60% to comply to the safety regulations.
0 – 40℃ / -20 – 60℃ *When the environmental temperature comes close 40 degrees, it is recommended to lower the load to 60% to comply to the safety regulations.